Skip to content
The Trade Hub
The Trade Hub
  • Q&A Forum
  • Regulatory Watch
  • Regulations
Log inSign up
Log inSign up
OverviewTARIC NomenclatureClassification GuideBTIEU Classification RulingsCJEU Case Law - Tariff ClassificationMarket IntelligenceOrigin of GoodsExport ControlCBAM CalculatorEUDR CheckerClassifyAI SHCustoms ValueIncoterms® 2020
Overview

Tariff Classification

TARIC Nomenclature
Classification Guide
BTI
EU Classification Rulings
CJEU Case Law - Tariff Classification
Market Intelligence

Origin of Goods

Origin of Goods
Origin guides

Export control

Export Control

Environmental

CBAM Calculator
EUDR Checker

Tools

ClassifyAI SH/TARIC
Customs Value
Incoterms® 2020
ClassifyAI SH/TARIC

Automated tariff classification with GRI justification

Classify a product
Need help?

Ask a question about this code or find a tariff classification expert.

Ask a question
  1. The Trade Hub
  2. ...Customs Intelligence
  3. Search

Customs Search

1 results for "8516808000"

Nomenclature codes

Binding Tariff Information (BTI)

See also

851680800080Other6%
GB1235348898516808000

WING ICE PROTECTION SYSTEM PROVIDES ELECTRO THERMAL ICE PROTECTION TO A DESIGNATED AREA OF AN AIRCRAFT WING SLATS. CAN BE USED ON BOTH MILITARY AND CIVIL AIRCRAFT

GB1217063108516808000

CARTRIDGE HEATER FOR FOR A PRINTER.THE CARTRIDGE HEATER IS OF A SPLIT SHEATH DESIGN. A CONTINUOUS RESISTOR IS PACKED INTO THE HIGHEST DENSITY INSULATION AND WELDED TO THE LEAD CONNECTIONS. THE LEAD WIRES CAN BE BENT SHARPLY WITHOUT EXPOSING THE CONDUCTOR. IT IS RATED TO 900 DEGREES FAHRENHEIT. STANDARD LEAD WIRES ARE 24 GAUGE INSULATED WITH TEFLON /FIBREGLASS

IE12NT-14-71-18516808000

RESISTIVE HEATING UNIT DESIGNED TO GENERATE HEAT THROUGH A RESISTANCE HEATER. IT CONSISTS OF LINEAR RESISTANCE WIRE WHICH IS ATTACHED TO FIBREGLASS MESH. THE MESH ACTS AS A METHOD TO EMBED THE RESISTANCE HEATER IN THE FLOOR PRIOR TO LAYING TILES. THE RESISTANCE WIRES ARE CONSTRUCTED BY BINDING SEVERAL RESISTANCE ALLOYS TO GENERATE THE REQUIRED RESISTANCE. THESE RESISTANCE WIRES ARE THEN EXTRUDED WITH POLYMERS TO ENSURE THEY ARE ELECTRICALLY SAFE

IE12NT-14-71-28516808000

RESISTIVE HEATING UNIT DESIGNED TO GENERATE HEAT THROUGH A RESISTANCE HEATER. THE FOIL PRODUCTS ARE CONSTRUCTED USING LINEAR RESISTANCE WIRE ENCAPSULATED IN ALUMINIUM FOIL. THE FOIL ACTS AS A METHOD TO DISTRIBUTE THE HEAT EVENLY. THE RESISTANCE WIRES ARE CONSTRUCTED BY WINDING RESISTANCE ALLOY AROUND A POLYESTER CORE TO GENERATE THE REQUIRED RESISTANCE. THESE RESISTANCE HEATERS ARE THEN EXTRUDED WITH POLYMERS TO ENSURE THEY ARE ELECTRICALLY SAFE.

IE-03NT-14-1941A18516808000

ELECTRIC HEATING RESISTOR - THIS IS AN ALLOY WIRE MOUNTED ON AN INSULATING CORE OF KEVLAR AND GLASS FIBRES. THE WIRE HEATS UP WHEN THE CURRENT IS PASSED THROUGH IT. THESE RESISTORS ARE USED AS IGNITION WIRE FOR ENGINES.