Skip to content
The Trade Hub
The Trade Hub
  • Q&A Forum
  • Regulatory Watch
  • Regulations
Log inSign up
Log inSign up
OverviewTARIC NomenclatureClassification GuideBTIEU Classification RulingsCJEU Case Law - Tariff ClassificationMarket IntelligenceOrigin of GoodsExport ControlCBAM CalculatorEUDR CheckerClassifyAI SHCustoms ValueIncoterms® 2020
Overview

Tariff Classification

TARIC Nomenclature
Classification Guide
BTI
EU Classification Rulings
CJEU Case Law - Tariff Classification
Market Intelligence

Origin of Goods

Origin of Goods
Origin guides

Export control

Export Control

Environmental

CBAM Calculator
EUDR Checker

Tools

ClassifyAI SH/TARIC
Customs Value
Incoterms® 2020
ClassifyAI SH/TARIC

Automated tariff classification with GRI justification

Classify a product
Need help?

Ask a question about this code or find a tariff classification expert.

Ask a question
  1. The Trade Hub
  2. ...Customs Intelligence
  3. Search

Customs Search

0 results for "90189084"

Binding Tariff Information (BTI)

See also

IEBTIIENEN004-2026-BTI1839018908400

PART OF A VESSEL CLOSURE MEDICAL DEVICE. THE COMPONENT IS CUSTOMISED AND FORMS PART OF THE MECHANISM IN THE CONTROL HANDLE WHICH CONTAINS A PRE-LOADED CLIP. THE MECHANISM DEPLOYS THE CLIP INTO THE BODY TO CLOSE AN OPEN WOUND. THE PART IS COMPOSED OF A 304 STAINLESS-STEEL TUBE WITH A CUSTOM-MOULDED POLYCARBONATE FIXTURE.

IEBTIIENEN004-2024-BTI38590189084

A MEDICAL COMPONENT, A DILATOR LOCK WHICH IS MANUFACTURED SPECIFICALLY TO CONNECT INTO A VALVE ASSEMBLY OF A MEDICAL DEVICE USED IN ENDOVASCULAR REPAIR PROCEDURES. THE COMPONENT SERVES AS A LOCKING MECHANISM WITH AN ARROW INDICATING TO THE USER IF THE ASSEMBLY IS LOCKED OR UNLOCKED.

IEBTIIENEN004-2024-BTI19290189084

A single use component of a medical device used in endovascular repair procedures. The component is in the form of an assembly consisting of a dryseal valve designed to enable the introduction of multiple devices during the medical procedure and minimise associated blood loss, a stopcock valve for inflating the dryseal valve and a second stopcock valve for flushing saline solution through the device, connected by tubing. The dryseal valve in the assembly has ‘lock/unlock’ icons which must align with the ‘pointer’ icon on the dilator (not subject of this BTI) to be inserted through the valve. The assembly comes in multiple sizes ranging from 10Fr to 26Fr in diameter and varying lengths from 33cm to 65cm. The assembly is made of plastic.

IEBTIIENEN004-2021-BTI2179018908400

Lever - This is an essential part of a vessel closure delivery system, which is a medical device. The material composition is of injection moulding grade of abs (acrylonitrile butadiene styrene). The lever is used on the vessel closure device to open and close the foot. This allows the surgeon to identify where the device is located in the patient body during use. The lever is marked with two numbers which indicate the lever position during surgery.

IEBTI21NT-14-13309018908400

VASCULAR CLOSURE SYSTEM. IT IS DESIGNED TO DELIVER A NITINOL (NICKLE AND TITANIUM ALLOY) CLIP TO CLOSE FEMORAL ARTERY ACCESS SITES FOLLOWING PERCUTANEOUS CATHETERISATION PROCEDURES. THE SYSTEM CONSISTS OF A CLIP APPLIER AND A 6F EXCHANGE SYSTEM. AN IMPLANTABLE CLIP IS MOUNTED ON THE CLIP APPLIER WHICH DELIVERS THE CLIP THROUGH THE EXCHANGE SHEATH FOR EXTRAVASCULAR CLOSURE OF ACCESS SITES.

TARIC Nomenclature

25 000+ codes

Classification Guide

1 095 HS4

BTI

1 000 000+ BTI