Skip to content
The Trade Hub
The Trade Hub
  • Q&A Forum
  • Regulatory Watch
  • Regulations
Log inSign up
Log inSign up
OverviewTARIC NomenclatureClassification GuideBTIEU Classification RulingsCJEU Case Law - Tariff ClassificationMarket IntelligenceOrigin of GoodsExport ControlCBAM CalculatorEUDR CheckerClassifyAI SHCustoms ValueIncoterms® 2020
Overview

Tariff Classification

TARIC Nomenclature
Classification Guide
BTI
EU Classification Rulings
CJEU Case Law - Tariff Classification
Market Intelligence

Origin of Goods

Origin of Goods
Origin guides

Export control

Export Control

Environmental

CBAM Calculator
EUDR Checker

Tools

ClassifyAI SH/TARIC
Customs Value
Incoterms® 2020
ClassifyAI SH/TARIC

Automated tariff classification with GRI justification

Classify a product
Need help?

Ask a question about this code or find a tariff classification expert.

Ask a question
  1. The Trade Hub
  2. ...Customs Intelligence
  3. Search

Customs Search

1 results for "9021909000"

Nomenclature codes

Binding Tariff Information (BTI)

See also

902190900080Other6%
IEBTI18NT-14-73329021909000

THE ITEM IS A STAINLESS STEEL ETCHED LINK MEDICAL COMPONENT FOR NEUROVASCULAR IMPLANT COIL. IT CONNECTS THE DETACHABLE COIL TO THE NEUROVASCULR IMPLANTABLE COIL. WHEN THE NEUROVASCULAR COIL IS IMPLANTED THE ETCHED LINK REMAINS IN THE BRAIN ATTACHED TO THE IMPLANTED COIL AND THE DETACHABLE COIL IS REMOVED

IEBTI18NT-14-71409021909000

A CHASSIS MOULDING OF PLASTIC BEING PART OF A WEARABLE DEVICE THAT IS USED FOR AUTOMATED INSULIN DELIVERY. IT IS USED INTERNALLY WITHIN AN INSULIN DELIVERY DEVICE TO HOLD ESSENTIAL COMPONENTS IN PLACE. IT IS SPECIFICALLY SHAPED WITH GROOVES AND CUTOUTS AND HOLES AND CANNOT BE USED IN ANY OTHER DEVICE. IT IS BULK PACKED AND SHIPPED

IEBTI18NT-14-6942-019021909000

AN IMPLANTABLE DEVICE USED TO PROVIDE MEDICAL THERAPY BY STIMULATING THE NERVES RESPONSIBLE FOR ACTIVATING THE KEY MUSCLES IN THE LOWER BACK. IT CONSISTS OF AN IMPLANTABLE PULSE GENERATOR, LEADS AND AN ACTIVATOR. THE IMPLANTABLE PULSE GENERATOR IS IMPLANTED BENEATH THE SKIN OF A PATIENT AND IS CONNECTED BY LEADS WHICH WILL TRANSMIT ELECTRICAL CURRENT TO THE AREA OF THE BODY THAT REQUIRES THERAPY. THE PRINCIPLE FUNCTION OF THE ACTIVATOR IS TO COMMUNICATE WITH THE IMPLANTABLE PULSE GENERATOR TO COMMENCE A SESSION OF INTERNAL STIMULATION TO THE NERVE ENDINGS. A TORQUE WRENCH WHICH IS USED FOR INSERTION IS SUPPLIED IN THE SAME PACKAGE AS THE PULSE GENERATOR AND THE SYSTEM MAY ALSO INCLUDED ANCILLARY ACCESSORIES SUCH AS AN INTRODUCER OR PROGRAMMING WAND.

IEBTI18NT-14-6942-029021909000

IMPLANTABLE PERCUTANEOUS LEAD: THE CONTENTS OF THE PRODUCT CONTAINS A PERCUTANEOUS LEAD (1), STYLET (2) AND SUTURE SLEEVE (2). THEY ARE IMPLANTED INTO THE BODY AND THE LEADS ARE CONNECTED TO AN IMPLANTABLE PULSE GENERATOR TO DIRECTLY STIMULATE NERVES WHICH ACTIVATES LUMBER MUSCLES WHICH ARE FUNCTIONING DEFECTIVELY. PRESENTED IN STERILISED PACKAGING.

IEBTI18NT-14-6942-039021909000

ACTIVATOR CONSISTING OF A CONTROL MODULE ATTACHED TO AN ANTENNA VIA A CABLE WHICH COMMUNICATES WITH AN IMPLANTABLE PULSE GENERATOR VIA SHORT-RANGE INDUCTIVE TELEMETRY. THE PULSE GENERATOR CANNOT OPERATE WITHOUT THE ACTIVATOR. ITS PRINCIPLE FUNCTION IS TO COMMUNICATE WITH THE IMPLANTABLE PULSE GENERATOR TO COMMENCE MEDICAL THERAPY BY STARTING A SESSION OF INTERNAL STIMULATION TO NERVE ENDINGS WHICH ACTIVATES LUMBER MUSCLES WHICH ARE FUNCTIONING DEFECTIVELY. IT IS ALSO USED FOR THE FOLLOWING FUNCTIONS: TO PAUSE/STOP A SESSION, TO CHECK SESSION STATUS AND TO INDICATE AN ISSUE WITH THE IPG (FOR E.G. LOW BATTERY POWER). TWO AA BATTERIES ARE ALSO INCLUDED IN THE PACKAGE.