Électronique
Equipements electroniques a usage general, y compris les enregistreurs a bande magnetique (analogiques >4 MHz/canal, numeriques >360 Mbit/s), les generateurs de signaux, les oscilloscopes, les analyseurs de spectre et les synthetiseurs de frequence. Les seuils de controle portent sur la bande passante, le debit et la frequence de sortie.
| Reference | Parametre | Seuil |
|---|---|---|
| 3A002.a | analog recorder bandwidth per channel | > 4 MHz |
| 3A002.a | digital video transfer rate | > 360 Mbit/s |
| 3A002.g | frequency switching time | < 100 µs |
| 3A002.g | SSB phase noise at >=10 GHz | < -80 dBc/Hz |
| 3A002.h | synthesis rate (10+ bit DAC) | >= 2.5e9 samples/s |
| 3A002.h | clock frequency (12+ bit DAC) | >= 250 MHz |
| 3A002.c.1 | "Signal analysers" having a 3 dB resolution bandwidth (RBW) | > 40 MHz anywhere |
| 3A002.c.1 | (RBW) exceeding 40 MHz anywhere within the frequency range | > 318 GHz but |
| 3A002.c.1 | 8 GHz but not | > 37 GHz |
| 3A002.c.1 | 8 GHz but | <= 37 GHz |
| 3A002.c.2 | etter) than -160 dBm/Hz anywhere within the frequency range | > 435 GHz but |
| 3A002.c.2 | 5 GHz but not | > 110 GHz |
| 3A002.c.2 | 5 GHz but | <= 110 GHz |
| 3A002.c.3 | "Signal analysers" having a frequency | > 110 GHz |
| 3A002.c.4 | sers" having all of the following: a. "Real-time bandwidth" | > 520 MHz |
| 3A002.d.1 | anywhere within the frequency range | > 318 GHz but |
| 3A002.d.1 | 8 GHz but not | > 37 GHz |
| 3A002.d.1 | 8 GHz but | <= 37 GHz |
| 3A002.d.1.a | ‘Pulse duration’ of | < 25 ns |
| 3A002.d.1.b | On/off ratio equal to or | > 65 dB |
| 3A002.d.2 | An output power | > 100 mW ( |
| 3A002.d.2 | ceeding 100 mW (20 dBm) anywhere within the frequency range | > 435 GHz but |
| 3A002.d.2 | 5 GHz but not | > 120 GHz |
| 3A002.d.2 | 5 GHz but | <= 120 GHz |
| 3A002.d.3.b | Less than 100 μs for any frequency change | > 22 GHz within |
| 3A002.d.3.b | 2 GHz within the frequency range | > 48 GHz but |
| 3A002.d.3.b | 8 GHz but not | > 318 GHz |
| 3A002.d.3.b | < 100 μs | |
| 3A002.d.3.b | 8 GHz but | <= 318 GHz |
| 3A002.d.3.d | Less than 500 μs for any frequency change | > 550 MHz within |
| 3A002.d.3.d | equency change exceeding 550 MHz within the frequency range | > 318 GHz but |
| 3A002.d.3.d | 8 GHz but not | > 37 GHz |
| 3A002.d.3.d | < 500 μs | |
| 3A002.d.3.d | 8 GHz but | <= 37 GHz |
| 3A002.d.3.e | Less than 100 μs for any frequency change | > 22 GHz within |
| 3A002.d.3.e | 2 GHz within the frequency range | > 37 GHz but |
| 3A002.d.3.e | 2 GHz within the frequency range exceeding 37 GHz but not | > 75 GHz |
| 3A002.d.3.e | < 100 μs | |
| 3A002.d.3.e | 2 GHz within the frequency range exceeding 37 GHz but | <= 75 GHz |
| 3A002.d.3.g | Less than 100 μs for any frequency change | > 50 GHz within |
| 3A002.d.3.g | 0 GHz within the frequency range | > 75 GHz but |
| 3A002.d.3.g | 0 GHz within the frequency range exceeding 75 GHz but not | > 110 GHz |
| 3A002.d.3.g | < 100 μs | |
| 3A002.d.3.g | 0 GHz within the frequency range exceeding 75 GHz but | <= 110 GHz |
| 3A002.d.4.a | e of 10 Hz ≤ F ≤ 10 kHz anywhere within the frequency range | > 32 GHz but |
| 3A002.d.4.a | 2 GHz but not | > 110 GHz |
| 3A002.d.4.a | 2 GHz but | <= 110 GHz |
| 3A002.d.4.b | e of 10 kHz< F≤ 100 kHz anywhere within the frequency range | > 32 GHz but |
| 3A002.d.4.b | 2 GHz but not | > 110 GHz |
| 3A002.d.4.b | 2 GHz but | <= 110 GHz |
| 3A002.d.5.a | > 22 GHz within | |
| 3A002.d.5.a | 2 GHz within the frequency range | > 48 GHz but |
| 3A002.d.5.a | 8 GHz but not | > 318 GHz |
| 3A002.d.5.a | 8 GHz but | <= 318 GHz |
| 3A002.d.5.b | > 550 MHz within | |
| 3A002.d.5.b | Exceeding 550 MHz within the frequency range | > 318 GHz but |
| 3A002.d.5.b | 8 GHz but not | > 37 GHz |
| 3A002.d.5.b | 8 GHz but | <= 37 GHz |
| 3A002.d.5.c | > 22 GHz within | |
| 3A002.d.5.c | 2 GHz within the frequency range | > 37 GHz but |
| 3A002.d.5.c | 2 GHz within the frequency range exceeding 37 GHz but not | > 75 GHz |
| 3A002.d.5.c | 2 GHz within the frequency range exceeding 37 GHz but | <= 75 GHz |
| 3A002.d.5.d | > 50 GHz within | |
| 3A002.d.5.d | 0 GHz within the frequency range | > 75 GHz but |
| 3A002.d.5.d | 0 GHz within the frequency range exceeding 75 GHz but not | > 110 GHz |
| 3A002.d.5.d | 0 GHz within the frequency range exceeding 75 GHz but | <= 110 GHz |
| 3A002.d.6 | A maximum frequency | > 110 GHz |
| 3A002.e.1 | An output power | > 100 mW ( |
| 3A002.e.1 | 0 mW (20 dBm) anywhere within the operating frequency range | > 435 GHz but |
| 3A002.e.1 | 5 GHz but not | > 110 GHz |
| 3A002.e.1 | 5 GHz but | <= 110 GHz |
| 3A002.e.3 | ‘Nonlinear vector measurement functionality’ at frequencies | > 50 GHz but |
| 3A002.e.3 | ment functionality’ at frequencies exceeding 50 GHz but not | > 110 GHz |
| 3A002.e.3 | surement functionality’ at frequencies exceeding 50 GHz but | <= 110 GHz |
| 3A002.e.4 | A maximum operating frequency | > 110 GHz |
| 3A002.f | ving all of the following: 1. A maximum operating frequency | > 110 GHz |
| 3A002.g.3 | and c. Total power consumption of | < 1 W |
3A002.aRecording equipment, and specially designed test equipment therefor, as follows: a.1. Analog instrumentation magnetic tape recorders, including those permitting the recording of digital signals having a bandwidth exceeding 4 MHz per electronic channel or track; a.2. Digital video magnetic tape recorders having a maximum digital interface transfer rate exceeding 360 Mbit/s
3A002.gFrequency synthesised signal generators producing output frequencies, the control of which is derived from or controlled by the internal master frequency, having any of the following: 1. A 'frequency switching time' of less than 100 µs to any frequency within the synthesised range; or 2. Single sideband (SSB) phase noise of less than -80 dBc/Hz offset 100 Hz from the carrier at an output frequency of 10 GHz or more
3A002.hArbitrary waveform generators/function generators with any of the following: 1. A maximum synthesis rate of 2.5 × 10⁹ samples/s or more and a DAC resolution of 10 bit or more; or 2. A clock frequency of 250 MHz or more and a DAC resolution of 12 bit or more
3A002.a.1Not used;
3A002.a.2Not used;
3A002.a.3Not used;
3A002.a.4Not used;
3A002.a.5Not used;
3A002.a.6Digital data recorders having all of the following: a. A sustained ‘continuous throughput’ of more than 6,4 Gbit/s to disk or solid-state drive memory; and b. "Signal processing" of the radio frequency signal data while it is being recorded;
3A002.a.7Real-time oscilloscopes having a vertical root-mean-square (rms) noise voltage of less than 2 % of full-scale at the vertical scale setting that provides the lowest noise value for any input 3dB bandwidth of 60 GHz or greater per channel;
3A002.bNot used;
3A002.c"Signal analysers" as follows:
3A002.c.1"Signal analysers" having a 3 dB resolution bandwidth (RBW) exceeding 40 MHz anywhere within the frequency range exceeding 31,8 GHz but not exceeding 37 GHz;
3A002.c.2"Signal analysers" having a Displayed Average Noise Level (DANL) less (better) than -160 dBm/Hz anywhere within the frequency range exceeding 43,5 GHz but not exceeding 110 GHz;
3A002.c.3"Signal analysers" having a frequency exceeding 110 GHz;
3A002.c.4"Signal analysers" having all of the following: a. "Real-time bandwidth" exceeding 520 MHz; and b. Having any of the following: 1. 100 % probability of discovery with less than a 3 dB reduction from full amplitude due to gaps or windowing effects of signals having a duration of 8 μs or less; or 2. A ‘frequency mask trigger’ function with 100 % probability of trigger (capture) for signals having a duration of 8 μs or less;
3A002.c.5Not used;
3A002.dSignal generators having any of the following:
3A002.d.1Specified to generate pulse-modulated signals having all of the following, anywhere within the frequency range exceeding 31,8 GHz but not exceeding 37 GHz:
3A002.d.1.a‘Pulse duration’ of less than 25 ns; and
3A002.d.1.bOn/off ratio equal to or exceeding 65 dB;
3A002.d.2An output power exceeding 100 mW (20 dBm) anywhere within the frequency range exceeding 43,5 GHz but not exceeding 120 GHz;
3A002.d.3A "frequency switching time" as specified by any of the following:
3A002.d.3.aNot used;
3A002.d.3.bLess than 100 μs for any frequency change exceeding 2,2 GHz within the frequency range exceeding 4,8 GHz but not exceeding 31,8 GHz;
3A002.d.3.cNot used;
3A002.d.3.dLess than 500 μs for any frequency change exceeding 550 MHz within the frequency range exceeding 31,8 GHz but not exceeding 37 GHz;
3A002.d.3.eLess than 100 μs for any frequency change exceeding 2,2 GHz within the frequency range exceeding 37 GHz but not exceeding 75 GHz; or
3A002.d.3.fNot used;
3A002.d.3.gLess than 100 μs for any frequency change exceeding 5,0 GHz within the frequency range exceeding 75 GHz but not exceeding 110 GHz;
3A002.d.4A single sideband (SSB) phase noise, in dBc/Hz, specified as being any of the following:
3A002.d.4.aLess (better) than -(126 + 20log10F - 20log10f) anywhere within the range of 10 Hz ≤ F ≤ 10 kHz anywhere within the frequency range exceeding 3,2 GHz but not exceeding 110 GHz; or
3A002.d.4.bLess (better) than -(206 - 20log10f) anywhere within the range of 10 kHz< F≤ 100 kHz anywhere within the frequency range exceeding 3,2 GHz but not exceeding 110 GHz;
3A002.d.5An ‘RF modulation bandwidth’ of digital baseband signals as specified by any of the following:
3A002.d.5.aExceeding 2,2 GHz within the frequency range exceeding 4,8 GHz but not exceeding 31,8 GHz;
3A002.d.5.bExceeding 550 MHz within the frequency range exceeding 31,8 GHz but not exceeding 37 GHz;
3A002.d.5.cExceeding 2,2 GHz within the frequency range exceeding 37 GHz but not exceeding 75 GHz; or
3A002.d.5.dExceeding 5,0 GHz within the frequency range exceeding 75 GHz but not exceeding 110 GHz; or
3A002.d.6A maximum frequency exceeding 110 GHz;
3A002.eNetwork analysers having any of the following:
3A002.e.1An output power exceeding 100 mW (20 dBm) anywhere within the operating frequency range exceeding 43,5 GHz but not exceeding 110 GHz;
3A002.e.2Not used;
3A002.e.3‘Nonlinear vector measurement functionality’ at frequencies exceeding 50 GHz but not exceeding 110 GHz; or
3A002.e.4A maximum operating frequency exceeding 110 GHz;
3A002.fMicrowave test receivers having all of the following: 1. A maximum operating frequency exceeding 110 GHz; and 2. Being capable of measuring amplitude and phase simultaneously;
3A002.g.1"Space-qualified";
3A002.g.2Non-rubidium and having a long-term stability less (better) than 1 × 10^-11/month; or
3A002.g.3Non-"space-qualified" and having all of the following: a. Being a rubidium standard; b. Long-term stability less (better) than 1 × 10^-11/month; and c. Total power consumption of less than 1 W;
Note de decontrole
Les oscilloscopes de laboratoire standard et les generateurs de signaux sous les seuils de bande passante/frequence ne sont pas controles.
Note Générale sur la Technologie (NGT)
L'exportation de 'technologie' 'nécessaire' au 'développement', à la 'production' ou à l''utilisation' d'articles contrôlés dans les catégories 0 à 9 est contrôlée conformément aux dispositions de cha...
Note Générale sur les Logiciels (NGL)
Les Listes ne contrôlent pas les 'logiciels' qui sont : 1. Généralement accessibles au public du fait qu'ils sont : a. Vendus sans restriction à partir de points de vente au détail, par l'un des moyen...